Most of the new materials and prefabricated structures introduced into the construction and decoration sector almost completely exclude free air movement. The tightness provided by them along with the pluses brought a significant minus - violation of ventilation processes.
They simply need to be restored, because, you see, without a regular supply of fresh air into the room, it is impossible to live in it!
We know how to solve such a difficult problem: exhaust ventilation through the wall to the street will form the normal movement of air masses. A small wall device will ensure exhaust flow and excellent air exchange.
Our proposed article will acquaint you with the intricacies of choosing a valve for organizing exhaust ventilation, with the rules for its installation and operation. The information submitted for consideration is confirmed by photo materials, diagrams and video instructions.
Common ventilation problems
Natural ventilation of living quarters is based on the presence of micro-cracks characteristic of wooden window structures. Through such small openings, air regularly flowed outside and was removed from the house through ventilation ducts arranged in building structures.
So in the apartment there was a constant change of air masses, contributing to a normal level of humidity, removing unpleasant odors, etc.
Regular renewal of the air mass, occurring naturally through a loose fit of window sashes and door leafs, as well as by ventilation, forms a microclimate optimal for life, removes excess moisture, carbon dioxide and other harmful toxic substances
Improper air exchange in the house is a practically unavoidable problem when taking measures to reduce heat loss. When installing new windows and doors, trying to minimize heat leakage, few people think about ventilating their homes.
But soon the problems appear in the form of a stuffy atmosphere, the growth of mold in the bathroom and other similar phenomena. Soon, the abnormal microclimate begins to negatively affect the health status of those who live in such a house.
Air handling units of various types and types help to deal with excessive sealing of the premises, but this may not be enough for normal ventilation.
The draft of natural exhaust ventilation is often weak, or even completely absent. Due to problems with the installation of ventilation structures, part of the air masses that must be removed from the house penetrates back.
Lack of ventilation or its incorrect organization is dangerous not only for people's lives. Moisture condensing on the surfaces, not eliminated as a result of ventilation, causes premature failure of structures, communications, decoration
On the draft state in the ventilation system of a house or apartment, the air temperature in the street is also reflected, or rather, the temperature difference indoors and outdoors.
In winter, this gap is large enough to provide good traction. But in the summer, the temperature difference between the external and internal air is not so significant, and this affects the quality of traction is not too good.
For these reasons, you should think about the need to install special exhaust valves. They will ensure quick and effective removal of exhaust air from the home, as well as prevent its back penetration.
Stagnant stale air and excessively humid environment contribute to the resettlement of fungal colonies, threatening living with serious diseases and the destruction of building materials (+)
Varieties of exhaust valves
The low efficiency of exhaust ventilation is most often due to various reasons, for example, a violation of the patency of the channels or their tightness.
In multi-storey buildings, such situations often arise due to flaws in the repair process, and it is not always possible to eliminate the consequences of errors and restore the normal state of ventilation ducts.
Depending on the installation location of the exhaust ventilation, use a horizontal or vertical valve model and a fan with a sufficiently high performance (+)
In this case, the exhaust valves may be more than appropriate. The design of these devices is very simple, their main purpose is to let air flow out and not allow them to penetrate back. By the type of installation, such valves are divided into horizontal and vertical, it all depends on the direction of air flow.
If the exhaust flow should move vertically, choose a valve with horizontal installation. A horizontal valve is needed to divert air horizontally. Typically, exhaust valve models are equipped with a fan. They are used where the removal of air from the premises must be carried out forcibly.
Another significant point is the noise level that a working device emits. The lower the sound effects from the expanding blades of the valve and / or the rotary fan, the better. A lot of useful information can be found in the product data sheet.
When choosing an exhaust valve that will be installed in a wall, you should take into account the thickness of this wall, as well as the material in which you will have to make a hole
Wall construction
A conventional exhaust valve consists of three main parts:
- flange;
- flaps;
- decorative lattice.
The round flange is a connecting element that allows you to connect the valve to the ventilation duct. The grill is a decorative element that simply masks a hole in the wall, and also prevents accidental ingress of large debris. The basis of the design is a damper.
This is a movable petal, round or square configuration, mounted on an axis. It can open only in one direction, ensuring the correct movement of the air flow. The design may also include a plumb line that allows the valve to remain closed when the fan is off.
An axial exhaust fan consists of elements such as a power cable (1), an air intake grille (2), a switch (3), a switch cable (4), an impeller (5), shutters (6)
For industrial facilities, it is usually recommended to select a valve with good explosion-proof characteristics, but for residential premises other features are important. For example, having a rubber gasket that can reduce the amount of noise will be useful.
One common exhaust valve option is a butterfly design. It consists of two blades mounted on a central axis. Another popular design of such devices is called flap, it includes a series of parallel mounted blades that move on the principle of blinds.
Installation of the axial fan for the exhaust type of ventilation is carried out according to a single scheme for all systems:
Image Gallery
Photo from
Step 1: Buy an Exhaust Fan
Step 2: Connect the power line to the device
Step 3: Mark points for mounting the instrument body
Step 4: Drilling the hole for the dowels of the fasteners
Step 5: Fixing the bottom of the fan housing
Step 6: Connect the fan to the wiring
Step 7: Installing the protective and decorative panel
Ceiling Fan Installation
Such a fan is often mounted in bathrooms and bathrooms.
Reasonable choice
Most often, the exhaust ventilation valves in the wall are made of metal or durable plastic. For conditions of elevated temperature and humidity, for example, for a bath, plastic products are not suitable, but they have proven themselves in less difficult situations.
When choosing a valve, its cross-section should be taken into account: rectangular or round.
The most important indicator is the air flow rate for which the device is designed. The most common are models designed for a flow of 4-6 m / s.
For the organization of forced exhaust ventilation in an apartment or house, you can use a design consisting of a fan and a check valve
If the valve is selected for the natural ventilation system, it is very important that the valve flap elements are sensitive to even small air flows. But for systems with weak traction, the presence of an exhaust fan is necessary, therefore, such sensitivity is not needed.
But here it is important to choose a fan that is suitable for power depending on the volume of the room for which the device is selected. So, for the kitchen, the fan power is calculated using a raising factor equal to ten, and for the bathroom this figure can be seven units.
In multi-storey buildings, the exhaust ventilation pipe must be led out one meter above the roof so that unpleasant odors do not penetrate from the lower floors to the upper ones.
Subtleties of the construction of exhaust ventilation in the wall
In private homes, and even in multi-story buildings, in many cases it is more convenient to make a ventilation outlet directly through the wall. To do this, models of exhaust valves with a fan are used, which are inserted into the mounting sleeve intended for their location.
You can also use overhead fan models that are mounted on the inside of the wall.
To install the exhaust ventilation valve in the wall, you first need to make markings and drill a hole of the right size in it
To install such a simple design, you will need to make a sufficiently large hole for the installation of ventilation in the outer wall of the house. But first you need to choose the right device.
Manual models have a reasonable price, but they are extremely inconvenient to use, because you will constantly have to remember the need to turn the exhaust valve on or off.
An exhaust fan is installed on the inside of the hole made in the wall, and a check valve and a protective grill are installed on the outside
To automate the process, you can use a timer. It will be necessary to select a time schedule, in accordance with these settings, the valve will turn on and off at the specified time. More effective may be the use of a sensor that responds to the humidity level in the room.
In this case, the device will begin to work when the air in the room becomes too humid, and when the humidity decreases, the fan stops. When choosing automatic control devices, make sure that when the power is turned off, the previously set settings are saved.
To ensure good air exchange in the room, it is necessary to use a sufficiently powerful fan. A weak unit in this regard simply cannot cope with the movement of a large volume of air masses; as a result, ventilation will not be effective enough.
The choice of location for installing the wall ventilation valve is focused on the requirements specified in the instructions by the device manufacturer
In calculations, they usually use a simple formula:
M = O * B
Where:
- M - required fan power;
- О - volume of the room in which the device will be installed;
- In - increasing the coefficient of air exchange.
It is possible to calculate the volume of a room from a school course in mathematics as the product of the area and the height of the room. The air exchange coefficient is determined depending on the purpose of the room.
This indicator should be:
- for a separate toilet - 8;
- for the kitchen - 15;
- for a bathroom or a combined bathroom - 20.
It remains only to determine the volume of the room and multiply it by the appropriate coefficient to get an indicator that will help you choose a valve with a sufficiently powerful fan. Do not take an excessively powerful model, it will only cause unnecessary costs and will not affect the ventilation process favorably.
When calculating the power of the exhaust fan, it is necessary to take into account the sensitivity of such equipment to the resistance of the system. The presence of a decorative grille and valve can reduce the speed of movement of the air flow by three to five or even ten times. Therefore, you should not choose a device with a minimum size and power.
Fan performance should be sufficient to allow exhaust air to escape through the valve from adjacent rooms, and not just from the room in which the device is installed. Before starting work on installing an exhaust valve with a fan, you must select a suitable location.
A vent for the exhaust valve is best done in the upper part of the outer wall, this position contributes to the effective removal of exhaust air
To do this, use a wall that is as far as possible from the place where fresh air is taken. Typically, ventilation is installed in the walls or windows of rooms such as a bedroom or living room.
For exhaust ventilation, a kitchen or a bathroom is more suitable. As a result, unpleasant odors, excess water vapor, etc. are also discharged with the exhaust air.
A vent for the exhaust valve must be made at the top of the wall. First, marking is performed, then drilling begins. A suitable hole is made with a drill and a core drill. Sometimes you have to use a special tool with a diamond nozzle.
The hole for the exhaust valve must match the size and configuration of the fan. This is usually a round device, but sometimes it is more convenient to use a device with a square case. In this case, the hole for the valve must be hollowed out using a hammer drill with a nozzle in the form of a scapula.
The diameter and shape of the hole in the wall for installing the exhaust valve must match the characteristics of the fan that comes with the device
Such work is usually accompanied by a large amount of dust, from which even the use of an industrial vacuum cleaner does not save. Before drilling, cover surfaces with a film or other suitable materials to protect them from contamination.
A core drilling machine can be used to drill particularly thick exterior walls of durable materials. This is expensive equipment that is cheaper to rent than to buy. Specialized firms provide core drilling services at a relatively low price, which depends on the drilling depth and wall material.
For drilling thick walls when installing an exhaust valve for forced ventilation, you can rent a core drill that can handle almost any material
During operation of such equipment, water cooling is used. At the same time, a device is used to collect waste material and water, but part of it will still hit the wall, this point should be taken into account before starting work.
After the hole has been prepared and cleaned of dust, a sleeve must be inserted into it, it is supplied with the valve.
Now you need to mark the mounting points of the fan. The device is fixed to the wall through the holes provided for this. As fasteners, dowels-spacers are most often used.Usually between the coupling and the wall there is a small gap through which air can subsequently penetrate.
All such cracks are gently blown with a mounting foam, which will provide the construction with the necessary tightness. After that, you can start installing the exhaust valve. Proceed very carefully so as not to damage the valve itself during installation and to prevent construction debris from entering it.
After installation, make sure that the valve flaps move freely, do not jam. After that, on the outside of the wall of the house you need to install a decorative grille that will close the hole and give the design an aesthetic appearance.
To improve the efficiency of the exhaust valve and reduce the likelihood of freezing in the winter, it is recommended to lay a layer of insulating material around the coupling. This point must be taken into account when calculating the diameter of the hole for the exhaust valve.
Some masters consider the coupling, which is equipped with an exhaust valve, not strong enough. They note that if necessary, the coupling may be accidentally damaged, and recommend replacing it with a piece of a stronger plastic pipe of the appropriate diameter.
The design of the exhaust ventilation must be airtight, therefore, after installing the main elements of the device, the slots must be blown with foam
If such a pipe turns out to be slightly wider than the fan that is inserted into it, it is possible to rewind it with electrical tape or other suitable material so that the device enters sufficiently tightly.
The fan should be supplied with power from the inside. The cable is led to the electrical panel, when connecting for safety reasons, use fusible fuses.
When installing the exhaust valve in the toilet, bathroom, the power supply can be connected so that the fan turns on simultaneously with the lighting. In this case, the timer can be set to turn off after a certain period after the light is turned off.
In order for exhaust ventilation in the toilet and the bathroom to work effectively, an air flow into these rooms should be ensured. Usually, special ventilation grilles are installed at the bottom of the doors for this.
The exhaust fan is fixed to the wall using the dowels that are included in the kit, and then closed with a special grille
During operation, the exhaust valve should be considered with such a problem as the occurrence of blockages. If debris enters the device, it may break the valve and make the fan difficult.
If this happens, the device will have to be dismantled, cleaned of impurities and installed again. Butterfly valves in winter can be covered with a layer of ice, which also leads to problems in the operation of the mechanism.
The process of installing the fan and the check valve through the wall is described in detail in this video:
The operation of a high-power exhaust fan with a non-return valve is demonstrated here. The device is characterized by increased strength and low noise during operation:
Exhaust ventilation is a necessary element for normal air exchange in the house. If it is installed correctly, then normal humidity and a favorable microclimate will be maintained in residential premises.
Have experience in installing a wall ventilation duct? Or have questions about the topic? Please share your opinion and leave comments. The feedback form is located below.